| TDS-10SH | TDS-350PE | TDS-150 |
Motor Type | Baldor Reliance AC Induction Motors | BaIdor Reliance AC Permanent Magnet Motors | AC Induction Motors |
Horsepower Rating | 1X400HP | 1×1,000 HP | 2 x 250 HP |
TDS Working Height | 15.3 ft (4,663 mm) | 20.8ft (6,339mm) | 16ft 8in (5,080 mm) |
Weight | 18,000 lb (8,164 kg) | 33,000 lb (14,968 kg) | 16,500 lb (7,484 kg) |
Transmission | | | |
GearRatio | 13.1:1 | 12.6:1 | 17.69:1 |
Drilling Parameters | | | |
Max Speed | 182RPM | 212 RPM | 200 RPM |
Max ContinuousTorque | 22,288 ft-lb (30,218 N-m) | 37,000 ft-lb (50,165 N-m) | 24,700ft-lb (33,488 N-m) |
Speed at Max ContinuousTorque | 85 RPM | 145 RPM | 100 RPM |
Max Breakout Torque | 55,000 ft-lb (74,569 N-m) | 65,000 ft-lb (88,128N-m) | 36,500 ft-lb (49,487 N-m) |
Max MakeupTorque | 42,680ft-lb (57,866N-m) | 60,000 ft-lb (81,349 N-m) | 36,500 ft-lb (49,487 N-m) |
Static Lock Brake | 50,000 ft-lb (67,790 N-m) | 55,000 ft-lb (74,569 N-m) | 36,500 ft-lb (49,487 N-m) |
Rating Capacities | | | |
Hoisting | 250 ton (226,796 kg) | 350ton (317,514 kg) | 150 ton (136,077 kg) |
Water Course | 3 in (76.2 mm) | 3 in (76.2 mm) | 234 in (69.8 mm) |
Washpipe Packing | 7,500 psi (517 bar) | 7,500 psi (517 bar) | 5,000 psi (344bar) |
PipeHandler | PH-55 | PH-65 | N/A |
Breakout Torque Capacity | 55,000 ft-lb (74,569 N-m) | 65,000 ft-lb (88,128 N-m) | 36,500 ft-lb (49,487 N-m) |
Drill Pipe Range | 2% in-5 in (73 mm-127 mm) | 3% in – 6% in (88.9 mm -168.2 mm) | 2% in – 416 in (73 mm -114.3 mm) |
Connection OD | 4 in-6% in (101.6mm-168.2 mm) | 4in-8W in (101.6 mm -215.9mm) | up to 6%’ OD |
IBOP Pressure Rating | 15,000 psi (1,034 bar) | 15,000 psi (1,034 bar) | 10,000 psi (689 bar) |
UpperlBOP | 6% in API Reg. RH Box (remote ope rated) | 6% in API Reg. RH Box (remoteoperated) | Dual Ball IBOP (1 Remote, 1 Manual) |
Lower IBOP | 6% in API Reg. RH Pin/Box (manual) | 6H in API Reg. RH Pin/Box (manual) | N/A |
Rot at io n/Orient at io n | 3607Unlimited | 360*/Unlimited | 3607Unlimited |
Other | | | |
Cooling System | Local Blower | RemoteWater Cooling | AirCool ed |
Hydraulic Power | Onboard | HPU Required | N/A |
Temperature Range | -40*C to *40*C (-40*F to +104*F) | -40℃ to +55*C (-40*F to 131‘F) | -40*C to *40*C (-40*Fto +104*F) |
Casing Running Tool Ready | No | Yes | No |